SIRIUS soft starter s00 17.6 a, 7.5 KW/400 V, 40 c 200-480 V AC, 110-230 V AC/DC screw terminals

Modified Industry Description

SOFTSTART,

AD Description

SIRIUS 3RW30181BB14 Soft Starter, 110 to 230 VAC/VDC Coil, 3 Poles, IP20

Vendor Description

The SIRIUS 3RW30 soft starters reduce the motor voltage through variable phase control and increase it in ramp like mode from a selectable starting voltage up to mains voltage. During starting, these devices limit the torque as well as the current and prevent the shocks which arise during direct starts or wye delta starts. In this way, mechanical loads and mains voltage dips can be reliably reduced. Soft starting reduces the stress on the connected equipment and results in lower wear and therefore longer periods of trouble free production. The selectable start value means that the soft starters can be adjusted individually to the requirements of the application in question and unlike wye delta starters are not restricted to two stage starting with fixed voltage ratios. The SIRIUS 3RW30 soft starters are characterized above all by their small space requirements. Integrated bypass contacts mean that no power loss has to be taken into the bargain at the power semiconductors (thyristors) after the motor has started up. This cuts down on heat losses, enabling a more compact design and making external bypass circuits superfluous. Soft starters rated up to 55 kW (at 400 VAC) for standard applications in three phase networks are available. Extremely small sizes, low power losses and simple commissioning are just three of the many advantages of this soft starter.

Specifications

Amperage Rating
17.6
Country of Origin
CZ
Dimensions
95 mm H x 45 mm W x 150 mm D
Frequency_Rating
50 to 60
Length1
4.8900
Number_Of_Poles
3
Operating_Temperature
-25 to 60
Phase
3
Special Features

  • 3 hp at 220/230 VAC, 10 hp at 460/480 VAC
  • Compact dimensions, short start up times, easy wiring and fast commissioning make themselves felt as clear-cut cost advantages
  • The bypass contacts of these softstarters are protected during operation by an integrated solid state arc quenching system
  • The new series of devices comes with the polarity balancing control method, which is designed to prevent direct current components in 2-phase controlled softstarters
  • The space required by the compact SIRIUS 3RW30 softstarter is often only about one third of that required by a contactor assembly for wye-delta starting of comparable rating
  • This is notable in particular for higher motor ratings which are only rarely available as fully wired solutions
  • This not only saves space in the control cabinet and on the standard mounting rail but also does away completely with the wiring work needed for wye-delta starters

Voltage Rating
200 to 480
Wattage
7.5